BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Asphalt Roofing Line | Revision: | 1 |
| Document #: | 11.1 | ||
| Class: | All | Date: | 11/08/91 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. Enclosure and vent to
afterburner w/ >0.3 sec at >1400oF 2. n/d |
1. BAAQMD Approved
Design and Operationb 2. n/d |
| NOx | 1. n/d 2. Natural gas firing |
1. n/d 2. Fuel Selection |
| SO2 | 1. n/d 2. Natural gas firing |
1. n/d 2. Fuel Selection |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. Natural gas firing and
afterburner w/ >0.3 sec at >1400oF 2. Natural gas firing and high velocity filter & mist eliminator |
1. BAAQMD Approved Design
and Operationb 2. BAAQMD Approved Design and Operationb |
| NPOC | 1. n/a 2. n/a |
1. n/a 2. n/a |
References
| b. BAAQMD |