BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Boiler - Wood Fired | Revision: | 1 |
| Document #: | 17.9.1 | ||
| Class: | All | Date: | 08/05/91 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/d 2. 0.027 lb/MMBtua |
1. n/d 2. Good Combustion Practicea |
| NOx | 1. n/s 2. 0.08 lb/MMbtua |
1. SCR + Combustion
Modifications 2. Selective Non-Catalytic Reduction (Ammonia Injection)a |
| SO2 | 1. n/s 2. 0.027 lb/MMBtua |
1. Dry Scrubber with
Baghouse 2. Limestone Injection with Baghousea |
| CO | 1. n/s 2. 0.038 lb/MMBtua |
1. Catalytic Oxidation 2. Good Combustion Practicea |
| PM10 | 1. <0.002 gr/dscf
@ 12% CO2 2. <0.01 gr/dscfa |
1. Multiclone and Baghousec 2. Multiclone and Baghousea |
| NPOC | 1. n/a 2. n/a |
1. n/a 2. n/a |
References
| a. CARB/CAPCOA Clearinghouse c. BAAQMD |